EATON BAB Series Thermal Magnetic Circuit Breakers


Eaton BAB Series thermal-magnetic circuit breakers are designed to protect electrical equipment and systems from damage due to short circuits and overcurrent conditions. They use both thermal and magnetic elements to detect and interrupt the circuit. These circuit breakers can be installed on d...evices using a bolt-on method, offering easy access to the device for maintenance and replacement and providing a secure, stable mount. They are available in single / double / three pole configurations to meet the needs of various applications.Read more

Filter
StyleModelAmpsVoltageNo. Of PolesHeightMounting TypeInterrupt RatingTrip TypeQuantityPrice
A
BAB2060H
--------€800.84
B
BAB2045H
--------€712.53
C
BAB3090HV
--------€1,639.51
D
BAB2040F
-120/240V21"Bolt-On10 kAICNon Interchangeable7€382.34
C
BAB3100HV
--------€1,243.22
E
BAB3015H
--------€211.03
C
BAB3100HT
--------€1,414.62
F
BAB3045H
--3-----€244.15
G
BAB2045
--------€106.45
F
BAB3050HV
--------€1,415.93
F
BAB3055H
--------€816.92
H
BAB2125
--------€342.43
I
BAB3060H
--------€231.11
J
BAB2040H
--------€886.49
K
BAB2050
--------€91.96
L
BAB2030H
--------€545.86
M
BAB2050H
--------€819.61
I
BAB3060HV
--------€1,061.47
C
BAB3100H
--------€292.03
N
BAB2055H
--------€667.82
O
BAB2060
--------€91.96
I
BAB3070HV
--------€1,338.94
P
BAB2060V
--------€331.39
Q
BAB2100
--------€183.94
R
BAB3080H
--------€292.03
S
BAB2090H
--------€888.17
T
BAB2090
--------€183.94
U
BAB2080
--------€183.94
V
BAB2070H
--------€1,068.64
W
BAB2035H
--------€175.30
F
BAB3040HV
--------€1,040.65
F
BAB3040H
--------€231.11
X
BAB3025H
--------€236.59
Y
BAB2020H
--------€141.82
F
BAB3035HV
--------€1,009.15
Z
BAB2015H
--------€141.82
A1
BAB2020V
--------€293.38
B1
BAB2025V
--------€357.91
F
BAB3030H
--------€211.03
C1
BAB3090H
--------€292.03
D1
BAB1000
-120/240V14 4/5"Bolt-On10 kAICNon Interchangeable7€61.69
E1
BAB2025
---1"----€91.96
F
BAB3035H
--------€244.15
F1
BAB1005
5A120/240V14 4/5"Bolt-On10 kAICNon Interchangeable7€287.79
G1
BAB2005
5A120/240V21"Bolt-On10 kAICNon Interchangeable7€374.49
H1
BAB1006
6A120/240V14 4/5"Bolt-On10 kAICNon Interchangeable7€227.02
I1
BAB2010HT
10A240V24 4/5"Bolt-On10 kAICNon Interchangeable7€998.09
J1
BAB2010V
10A120/240V21"Bolt-On10 kAICNon Interchangeable7€343.00
K1
BAB2010S
10A240V24 4/5"Bolt-On10 kAICNon interchangeable-€896.47
L1
BAB1010S1
10A240V14 4/5"Bolt-On10 kAICNon interchangeable-€639.64
L1
BAB1010
10A120/240V14.7"Bolt-On10 kAICNon Interchangeable7€37.07
M1
BAB2010C
10A120/240V23"Bolt-On10 kAICNon Interchangeable7€354.62
N1
BAB2010T
10A120/240V24 4/5"Bolt-On10 kAICNon Interchangeable7€268.48
L1
BAB1010V
10A240V13 1/2"Bolt-On10 kAICNon interchangeable-€140.57
O1
BAB3010H
10A240V34.9"Bolt-On10 kAICNon interchangeable32€281.68
L1
BAB1010S
10A240V14 4/5"Bolt-On10 kAICNon Interchangeable--
RFQ
O1
BAB3010HS
10A240V34.9"Bolt-On10 kAICNon interchangeable32€1,496.35
P1
BAB1010E
10A240/415V14.7"Bolt-On3 kAICNon Interchangeable7€205.76
K1
BAB2010
10A120/240V24 4/5"Bolt-On10 kAICNon Interchangeable7€88.18
Q1
BAB2015F
15A120/240V21"Bolt-On10 kAICNon Interchangeable7€306.57
R1
BAB2015I
15A120/240V23"-10 kAICInterchangeable-€256.32

Working Mechanism

  • These circuit breakers use a combination of thermal and magnetic technology to detect and interrupt overcurrents.
  • The thermal element (bi-metallic strip) responds to prolonged overcurrents by monitoring the heat generated by the current flowing through the circuit breaker.
  • The magnetic element (electromagnet) responds to sudden, large overcurrents by monitoring the magnetic field generated by the current.
  • If the temperature exceeds a certain threshold, both thermal and magnetic elements will trip and open the circuit.

Frequently Asked Questions

How to reset the circuit breaker once tripped?

Users can manually reset the circuit breaker after clearing the fault by pushing the toggle at the centre of the circuit breaker.

What are non-interchangeable circuit breakers?

Non-interchangeable circuit breakers have unique characteristics and ratings that are matched to meet the specific requirements of the equipment. Hence, they are not suitable for replacing or substituting with a different type of circuit breaker without compromising the safety or performance of the electrical system or equipment.

We are here to help!

Looking for a part not listed here?