LITTLE GIANT PUMPS Condensate Pumps

Designed for removing condensate (water) from air conditioners, condensing boilers, refrigerators & gas furnaces. Comprise a thermal overload protected motor to protect the sensitive components from excessive temperatures

Filter

Little Giant condensate pumps are used in closed circuit air cooling & heating units like HVAC systems and industrial boilers for circulating or transferring condensed water vapour away from...Read more
LITTLE GIANT PUMPS -

Vcl-45 Series Condensate Pumps

StyleModelMax. Flow Rate @ 15 Ft.FrequencyCord LengthTank MaterialHousing MaterialWattagePhaseFlow Rate @ 5 Ft.Price
A5532406.3 GPM60 Hz2.9 ft.ABS PlasticPlastic185 WSingle7.3 GPM€653.05
A553245380 GPH50/60 Hz6 ft.ABSABS250 W1440 GPH€815.51
StyleModelFrequencyMax. PressureOverall HeightHpPump TypeTank CapacityMax. Flow Rate @ 5 Ft.Max. Flow Rate @ 10 Ft.Price
A55446150/60 Hz7.4 psi7"1/30 hpStandard0.5 gal.1.2 GPM0.8 GPM€158.24
A55443560 Hz8.7 psi7.03"1/30 hpStandard0.5 gal.1.2 GPM0.8 GPM€137.71
LITTLE GIANT PUMPS -

VCMA-15 Series Condensate Removal Pump

StyleModelPump TypeMin. Temp.HpTank CapacityMax. Flow Rate @ 15 Ft.Intake Connection StyleDischarge Connection StyleTurn On LevelPrice
A554411Condensate Removal Pump140°F1/50 hp0.5 gal.-----
RFQ
B554401Condensate Removal Pump75°F1/50 hp0.5 gal.----€83.34
A554415Standard-1/50 hp0.5 gal.0 GPMOpenBarbed2 1/2"€164.81
LITTLE GIANT PUMPS -

Condensate Pump

StyleModelHpPump TypeTank CapacityIntake Connection StyleDischarge Connection StyleTurn On LevelMax. Flow Rate @ 5 Ft.Max. Flow Rate @ 10 Ft.Price
A5513201/12 hpIn Pan1 gal.Screened SubmersibleMNPT4 1/2"--€522.36
B5532111/18 hpStandard1 gal.OpenBarbed3 1/2"--€321.22
C5532011/18 hpStandard1 gal.OpenBarbed3 1/2"4.2 GPM3.3 GPM€288.26
D5545421/30 hpStandard0.5 gal.OpenBarbed1 3/5"1.3 GPM1 GPM€167.99
E5544251/30 hpStandard0.5 gal.OpenBarbed2 1/2"--€145.70
F5535071/50 hpMini Split0.01 gal.OpenBarbed0.45"--€301.00
G5531011/50 hpStandard1 gal.OpenBarbed3 1/2"--€340.23
E5544051/50 hpStandard0.5 gal.OpenBarbed1.9"0.8 GPM0.4 GPM€152.79
H5505321/150 hpIn Pan0 gal.Screened SubmersibleBarbed1 3/4"2.4 GPM0 GPM€365.93
I5505211/150 hpIn Pan0 gal.Screened SubmersibleMNPT1 3/4"2.4 GPM0 GPM€296.51
LITTLE GIANT PUMPS -

Low Profile Condensate Pump, 1/30 Hp, 230 V, 50/60 Hz

ModelItemPrice (ex. VAT)
554202101CV8PLL€228.70
LITTLE GIANT PUMPS -

Condensate Removal Pump Reservoir, 110 To 240VAC, 1/4 Inch Outer Discharge

ModelItemPrice (ex. VAT)
553517CH6PBG€457.49
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/3 Hp, 380/460VAC

ModelItemPrice (ex. VAT)
553160104CR9QGQ€1,082.02
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/3 Hp, 208-230VAC

ModelItemPrice (ex. VAT)
553160102CR9QGP€1,015.79
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/3 Hp, 115VAC, 60 Ft

ModelItemPrice (ex. VAT)
553160101CR9QGN€993.23
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/8 Hp, 208-230VAC

ModelItemPrice (ex. VAT)
553130102CR9QGT€870.66
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/8 Hp, 115VAC, 30 Ft

ModelItemPrice (ex. VAT)
553130101CR9QGR€777.05
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/8 Hp, 277VAC, 30 Ft

ModelItemPrice (ex. VAT)
553130104CR9QGU€870.06
LITTLE GIANT PUMPS -

Low Profile Condensate Pump, 115 V, 60 Hz

ModelItemPrice (ex. VAT)
554201101CV8PLK€165.42
LITTLE GIANT PUMPS -

Sump Pump, 1/30 Hp, 230V

ModelItemPrice (ex. VAT)
554521BR7RTV-
RFQ
LITTLE GIANT PUMPS -

Condensate Removal Pump, 1/30 Hp, 230 V, 50/60 Hz

ModelItemPrice (ex. VAT)
554651CV8PLU-
RFQ
LITTLE GIANT PUMPS -

Condensate Removal Pump, 1/30 Hp, 230 V, 50/60 Hz

ModelItemPrice (ex. VAT)
554631CV8PLR-
RFQ
LITTLE GIANT PUMPS -

Condensate Removal Pump, 1/30 Hp, 115 V, 60 Hz

ModelItemPrice (ex. VAT)
554650CV8PLT-
RFQ
LITTLE GIANT PUMPS -

Condensate Removal Pump, 1/30 Hp, 115 V, 60 Hz

ModelItemPrice (ex. VAT)
554630CV8PLQ-
RFQ
LITTLE GIANT PUMPS -

Condensate Removal Pump, 1/30 Hp, 115 V, 60 Hz

ModelItemPrice (ex. VAT)
554642CV8PLP-
RFQ
LITTLE GIANT PUMPS -

Condensate Removal Pump, 1/30 Hp, 230 V, 50/60 Hz

ModelItemPrice (ex. VAT)
554621CV8PLN-
RFQ
LITTLE GIANT PUMPS -

Condensate Removal Pump, 1/30 Hp, 115 V, 60 Hz

ModelItemPrice (ex. VAT)
554620CV8PLM-
RFQ
12

Features

  • Little Giant condensate pumps comprise a motor with thermal overload protection to prevent damage to the sensitive components from excessive temperatures.
  • They are equipped with a fully automatic start / stop, safety switch & removable barbed check valve for reducing the risk of contamination & keeping the system / surrounding clean.
  • Most of the brand's condensate pumps are equipped with a reservoir / tank. However, the company's in-pan condensate pumps are sealed and submersible for in-pan placement & shallow pan tank applications to remove condensates.
  • Selected models (VCMX-20 Series) have rubber feet under their reservoir for slim footprint and dampening vibrations.
  • They are available in varying styles, namely compact submersible, high capacity, large reservoir, shallow pan & vertical variants.

Working Mechanism

  • Little Giant condensate pump is connected to a reservoir that collects the water / condensate from a condenser.
  • After a certain time, the water level rises in the reservoir of a selected condensate pump. The reservoir has a float that rises with the rising water level.
  • When the float reaches a specific point, it hits the float switch.
  • Once the float switch is triggered, the condensate pump turns on to remove the water from the reservoir.

Standards and Approvals

  • CE
  • CSA
  • cCSAus
  • UL

Frequently Asked Questions

What are some accessories compatible with Little Giant condensate pumps?

Little Giant condensate pumps can be fitted with a discharge adaptor, check valves & connecting equipment for discharging condensate safely while being connected to multiple types of equipment.

How to clean a Little Giant condensate pump?

  • Remove the tank / box containing the pump from the HVAC.
  • Empty the water from the tank.
  • Clean the pump using a soft brush.
  • Clean the plastic tank / box using a sponge soaked in vinegar.
  • Reconnect the reservoir & pump to the equipment.

How often should a condensate pump be inspected?

A condensate pump should undergo an annual inspection, maintenance & cleaning for efficient operation & safety. A condensate pump may get clogged due to dirt or debris. Users should thoroughly clean the pump at least once a year.